Ul fire rated assemblies. leakage rated door assemblies 15 f.


  1. Home
    1. Ul fire rated assemblies Oct 28, 2010 · Northbrook, Ill. Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire-rated ceiling assembly. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. V314. ul. See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States. Feb 9, 2021 · Fire Tested Assemblies . The main purpose of this Warnock Hersey Fire-Resistance Rated Wall Assemblies Warnock Hersey Product Listings • Standards products are certified against • ASTM, ISO, EN, CAN/CGSB, CAN/ULC • 1-Hour Fire Resistive Rated Wall Assemblies Click the link above, each design number below represents a James Hardie 1 hour Fire Resistive Wall Assembly. fire-resistance-rated glazing 7 b. ULC. ) Type of Protection Concrete Thickness & Type UL Design No. means of egress related door certifications 17 4. View Resources Determine the existing or planned building elements, including structural, mechanical, electrical, and finish materials, in the fire-rated assembly. Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. Deck Type Unrestrained Beam Rating 1. Testing is done by third-party laboratories Fire & Acoustic Data. Fire Resistance Design Manual (GA 600). JH/WA 60-01. Fire door assemblies typically have an hourly fire- protection rating that is nominally less than the corresponding hourly fire-resistance rating of the vertical (wall) assembly in which they are installed. Find fire-rated assemblies using USG products and systems, as well as the related evaluation reports and acoustical tests. and Canada. International Building Code (IBC), Underwriters Laboratories (UL) Fire Resistance Directory, Intertek Testing Se rvices' Di-rectory of Listed Products, and the Gypsum Associa-tion's . ThermalSafe achieves a one-, two-, or three-hour fire rating for walls and 1. SFSEI Fire Rated Assemblies for Cold-Formed Steel (Read Only) BuildSteel - A Guide to Fire and Acoustic Data for Cold-Formed Steel Floor, Wall and Roof Assemblies; UL® Fire Rating Assembly Look-Up; See below links for UL Design Listings or Intertek fire-rated designs: ProSTUD Approved UL Listings - UL R19331 Mar 5, 2021 · If a fire rating is desired for the exterior side further refine the results using “Rating Exposed to Fire on Exterior Face” in the Keyword box. ) 3/4 Unprotected Deck 21/2” LW D914 # ü ü ü Feb 16, 2024 · Only products which bear UL's Mark are considered Certified. Find and download resources for STC rated wall assemblies for your construction project. Find over 1800 fire-resistance-rated designs for walls, floors, beams and columns using UL Product SpecTM. leakage rated door assemblies 15 f. ca, and the Underwriters Laboratories web site at www. The catalog lists fire-resistance ratings, flame spread, noncombustibility and other fire-safety properties for various construction types and components. com Controlling spread of fire or products of combustion Section 300. VULCRAFT UL FLOOR - 2 | SEPTEMBER 2020 VULCRAFT® COMPOSITE DECK UL FIRE RATED ASSEMBLIES WWW. The AG Design Library is a robust tool to help you quickly find fire and sound rated assembly information: First, select the hourly rating needed Second, choose the type of design you are seeking (example – Walls/Partitions (steel framed), Floor/Ceiling (wood framed), etc. Estimate materials and find USG equivalents for your building projects. fire doors 8 d. fire door and window hardware and accessories 16 3. COM UL Fire Resistance Ratings Restrained Assembly Ratings (hr. Fire-resistance rated designs are used to achieve code compliant installations where the building codes require hourly rated designs. CGC provides resources for our UL wall assemblies for seamless integration into any construction project. 21 of the National Electrical Code ® (NEC ) covers electrical system penetrations through fire-resistant rated wall, partitions, floors, or ceilings. 28, 2010 - Underwriters Laboratories (UL) announces the launch of the ULtimate Fire Wizard, an Internet-based tool that allows architects, designers and code authorities to quickly identify fire-resistance-rated assembly designs that meet their project specifications. ) Type of Fire Rating: 2 hours: Assembly Construction. These are rated for fire exposure to one side or on both sides, depending on the application. 5VL 2VL 3VL 1. UL-rated assemblies such as fire-rated walls, ceilings, and floors are tested to withstand high temperatures for specified periods, preventing fire from spreading and providing time for evacuation and Outlet Boxes for Use in Fire Rated Assemblies 1 For more information visit www. Design Criteria and Allowable Variances Suited for both UL and ULC fire-rated designs and tested to ASTM E119 for fire rating. S. VULCRAFT UL FLOOR - 2 | MAY 2021 VULCRAFT® COMPOSITE DECK UL FIRE RATED ASSEMBLIES WWW. Use these instructions to create your UL Product iQ account and search the certification database for UL fire-rated assemblies, designs or systems. 5 hours for ceilings, making it the fire-resistant panel of choice. com. Fire-resistance-rated woodframe assemblies can be - found in a number of sources including the . This will help locate a design where the assembly is rated to exposure to fire on the exterior face. ) With over 200 UL fire rated assemblies, CEMCO’s CST/CST325, and FAS branded slotted tracks are the most popular choice for head-of-wall applications requiring 1 and 2 hour fire rated systems. Fire Resistance All ULC and UL %PDF-1. Browse 172 wall assembly files for various fire ratings, system thicknesses, and STC values. Find resources for UL wall assemblies for planning and estimation purposes. Design Criteria and Allowable Variances The most common fire-rated assemblies are floor/ceiling systems and wall assemblies. BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada. JH/WA 60-02 The fire-protective rated Uninsulated Ventilation Duct Assemblies and corresponding certification program were created for ventilation duct assemblies evaluated to the requirements of ISO 6944 that may not achieve an insulation rating and are for use in applications where an insulation rating (thermal protection) is not required. fire door and window frames 11 e. , Oct. These designs are identified in the ULC and UL Fire Resistance Directory, which is updated yearly and can be referenced at the Underwriters Laboratories of Canada website at www. Download here Nov 16, 2022 · What are UL allowances? One of the most common questions about fire-rated assemblies relates to things that can be changed. The In as few as 3-clicks, USG Assembly Builder™ allows you to define fire and acoustic performance criteria, select from certified assemblies, and implement them directly into your design and/or specification. 5VLP 2VLP 3VLP (hr. Ready to save time? Use this easy-to-follow installation guide to get started. Ridge Vent 9” Filtered Class-A Fire Rated Works year-round to efficiently ventilate an attic space. 7 %µµµµ 1 0 obj >/Metadata 1140 0 R/ViewerPreferences 1141 0 R>> endobj 2 0 obj > endobj 3 0 obj >/ExtGState >/ProcSet[/PDF/Text/ImageB/ImageC/ImageI Floor-Ceiling Assemblies. fire-protection-rated glazing 8 c. Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. . Metl-Span’s ThermalSafe® fire-resistant panels meet the required ratings for ASTM E 119, CAN/ULC 101, and UL 263 through Intertek and UL+ fire approval, in both the U. These fire door assemblies should be certified in accordance with UL 10A, 10B, and 10C as applicable, and installed in accordance with NFPA 80. An example of a design tested for exposure to fire on the exterior face is BXUV. Wall Assemblies. Each assembly design is tested under ASTM E119 Standard Test Methods for Fire Tests of Building Construction Materials. This Dec 6, 2023 · UL design V449 is ideal for occupancy separations and exterior walls that require a 2-hour fire rating. We test assemblies to international standards, establishing an hourly rating to provide evidence of compliance to code requirements. Find the right fire-rated assemblies and design details drawings for your architectural plans. Refer to the Fire Resistance Rating Summary to determine the UL design numbers and ceiling system products that correspond to the fire-rated assemblies that meet your needs. windstorm rated door assemblies 19 5. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States. Layer 1 - Structural Cement-Fiber Units: 1 layer 3/4" Thick, USG Structural Panel Concrete Subfloor (USGSP), with 6 days ago · They are specifically designed to resist the spread of fire, protecting both the building structure and its occupants in the event of a fire. Search by specific parameters or by assembly number to achieve code compliant installations. UL design V449 takes an existing 1-hour fire-rated wall that has one layer of ⅝" Type X gypsum board on each side and converts it to a 2-hour fire-rated wall assembly constructed from one side by adding two more layers of ⅝" Type X gypsum Mar 15, 2024 · Only products which bear UL's Mark are considered Certified. a. Fire-rated assemblies are tested and certified in their entirety. VULCRAFT. The best approach is to think of assemblies as minimums, so doing things like making stud spacing narrower or using a thicker-size gypsum board are typically allowed modifications. dex jedg ackgm ylwmic vzeyw kvl ggoa svm tbhyiy nhca